Auckland Homes Solutions

Fire remedial works

Location: Lancashire

Click Here To Enlarge This Photo Of Practical Solutions Midlands Limited

Practical Consulting Approach
New FD30s doors and door linings were installed in the following locations:

  • Boiler room
  • CCTV room
  • Dining room to front door
  • Kitchen to dining room
  • Kitchen to lounge
  • Lounge to downstairs
  • Lounge to front door
  • Room 1, 2, 3, 4, 5 & 6
  • Staff room

All the doors were made up in the workshop using FD30 door blanks and FD30 door linings with hardwood thresholds and zoo hardware. The glazing used on various doors consisted of 7.2mm pyro guard glass that was fitted in line with the manufacturer’s instructions and held in place with hardwood hockey stick beading.

The existing doors and frames were removed, and the new door sets were fitted to the openings using steel fixings on Blue60 packers and fire stopped using the Blue60 foam. When set, this was trimmed and finished with 69mm MDF architrave. Any larger gaps above the doors were filled using 4 x 2 CLS timber and covered with 12.5mm Fireline plasterboard. The doors were then painted with 2 coats of primer undercoat and 2 coats of white gloss to match the existing woodwork.

Additional works:

  • Additional works behind frames
  • Frame removal and plaster
  • Repairs to the walls and ceilings

There were large amounts of hidden work behind the existing frames that required remedial work to bring it up to a fire resisting standard. There were also numerous holes in the ceilings, these were trimmed square, and the plasterboard was replaced with two layers of 12.5mm Fireline plasterboard which was then filled and sanded to a finish to match the current ceiling.

Benefits

  •  Auckland Home Solutions properties are fully compliant and meet all the current standards, legislation, and regulations
  • Protect the residents and ensure they are safe
  • Protect the building from the spread of fire if a fire was to occur
  • Protect the escape routes and allow evacuation if a fire was to occur

Third party accredited installation gives the client assurances that the installation is to the correct standards
Back To List

For More Information on Our Services
Please Call Practical Solutions Midlands Limited Today on +44 (0)1332 980450

Send Us A Message

* * *
*
Find Us On Facebook
Cookies

This website uses cookies. Please let us know if you agree to the use of these cookies :
I Accept I Decline

Privacy Policy | 3rd Party Data Processors | Disable Cookies
Cookies